Commercial Reverse Osmosis sytems

 

 

Chris Camp Proprietor of Aquamaster Water Treatment

Reverse Osmosis is a process that is used to remove a wide range of salts to give water a high purity --Osmosis is a natural process involving fluid flow across a semi-permeable membrane barrier. It is the process by which nutrient feed the cells in our bodies and how water gets to the leaves at the top of the trees.

Reverse Osmosis systems, in their basic form, consist of a pressure pump, housing and the membrane. Water is forced into the housing under pressure and the pure water ( or permeate ) is collected and passed to service.

The size of the reverse osmosis system and choice of membrane will be determined by the permeat quality required, feed water salinity and permeate quality expected. Low energy membranes allow the unit to run at pressures around 150-200psi, and as such the pressure booster pumps required to generate the pure water are smaller, and the power consumption is reduced significantly.

Electrodeionization or EDI, is a continuous and chemical-free process of removing ionized and ionizable species from the feed water using DC power. EDI is typically used to polish reverse osmosis (RO) permeate and to replace conventional mixed bed ion exchange, which eliminates the need to store and handle hazardous chemicals used for resin regeneration and associated waste neutralization requirements.

 


 

C-600-05 / 600-800 LPH

8-400 20M3 / hr

8-200 RO System

B-2000

C-2000

8.75 ro system

8.75 K RO System

Comsoft RO System

Hydranautics Membranes

RoPro4-38

RoPro 4-48 2000-LPH

The Highest output model in 4" membrane series reverse osmosis system

 

The size of the RO and choice of membrane will be determined by the permeate quantity required, feed


water salinity and permeate quality expected. Low energy membranes allow the units to run at pressures around 150-200psi, and as such the pressure booster pumps required to generate the pure water are smaller, and the power consumption is reduced significantly.

These membranes will produce water quality of approx. 10 microsiemens from an input water of between 500-700 microsiemens. If higher permeate quality is required a different range of membranes with higher pressure pumps can be used. RO units are normally built and used as single units producing the quantity required during the working day.

If circumstances demand, the RO units can be duplexed with a central control panel being used to allow manual or automatic switching of the RO plant in service, and will also allow the units to run in parallel when the demand for water is higher, thus doubling the permeate production. Also for very high purity waters the RO can be manufactured in "double pass mode" - This means the permeate water from the first unit is fed as raw water into the second pass of the RO - This already high quality water will then be improved and a very pure water is produced, typically less than 1 microsiemen.

When sizing the pre-treatment system the quantity of water available on the raw water feed side needs to be checked carefully as the RO system needs a higher feed flow than it’s permeate output, as the recovery of the units is approx. 75% for the pure water. The 25% concentrate that is rejected by the
RO can be used for any application where soft water is required such as wash water, grey water for toilet flushing or in some cases cooling tower make-up. The use of this water
minimises any waste from the feed supply.

Combined sytem

RO sytem with pre softeneing and GAC filtration 1500- LPH

Double pass 1800lph

Double pass RO system 1800-LPH

Doublepass RO

Double pass RO with Degas membrane

RO with CEDI

RO system with CEDI 600-LPH @ 15Megohm

UF system

Ultra Filtration system

UF system 3

Ultra Filtration System

comsoft system

Comsoft system with permeate tank,pump,degasser and EDI 1200 IPH @15 Megohm

 

 

 

 

pretreatment skid

Pre-Treatment skid with softeneing, GAC filtration and reverse osmosis

 

 

 

 

Ropro 4.38DW

RoPro RoPro4-38 DW38 2000 lph

Tapered array with‘lowfouling’membranes for recovering swimming pool backwash water.Basic design can be used for high output tapered arrays with 4 ”membranes

 

 

 

CALL FOR INFORMATION AND PRICES


01354 740896
07534419276

 

Contact us by email below

aquamaster1st@yahoo.com


AREAS COVERED:- March, Cambridge, Peterborough, St.Ives, St.Neots,  Kings Lynn, Wisbech, Spalding, Market Deeping, Holbeach, Boston, Stamford, Bourn, Oundel, Ely, Newmarket, Grantham, Hunstanton, Heacham, Thetford, Bury St.Edmunds,  Huntindon, Oakham, Bishops Stortford, Hertford, Harlow, Epping, Haverhill, Ware, Hoddeston, Duxford, Sawbridgeworth, Bedford, Corby

.
OUTSIDE THESE AREAS PLEASE CALL.

Water Softening Cambridgeshire And Hertfordshire ~ Water Softeners Cambridgeshire And Hertfordshire ~ Water Purification Cambridgeshire And Hertfordshire
Reverse Osmosis Cambridgeshire And Hertfordshire ~ Legionella Risk Assessment Cambridgeshire And Hertfordshire
Water Filtering Cambridgeshire And Hertfordshire ~ Water Filtration Cambridgeshire And Hertfordshire

Search Engineered By First Search Consultancy

eXTReMe Tracker
Copyright all contents reserved